How to select the high master lights – 12 tip from engineer
How to choose the led high mast light building the best high mast lighting system to help you find the outdoor stadium lighting manufacturer
High mast lighting is commonly used in large outdoor areas such as airport, stadium, parking lot, sea port and mining area. LED has high energy efficiency, flexibility and durability, in addition, the best high mast lighting system should have appropriate illumination level, lighting uniformity and color temperature. Let’s explore how to choose the best lighting for high poles and why LED are used instead of traditional metal Halide lamps. We’ve come up with 12 of the best tips
1. Illumination level calculation
To calculate the power required for the high mast light, we first need to understand the lighting requirements. Approximately 300 to 500 Lux for training sports. Airport and sea port is about 50 to 200 Lux . We need to know the correct size of the site and the location of the light poles so that we can use the DIAlux software to simulate the requirement.
2.High illuminate uniformity
The best high mast lighting system should provide highly uniform lighting. It indicates the ratio between the minimum and the average or between the minimum and the maximum. We can see that the maximum illumination uniformity is 1. The requirements of different venues are also different, and the most stringent requirements should be large stadiums. Because the uniformity of lighting will affect the performance of athletes and determine the quality of images transmitted by cameras, the uniformity of these venues is generally above 0.8.
For parking, airports and ports, 0.35 to 0.5 is appropriate. Why do we need uniform lighting? This is because uneven bright and dark spots can cause eye strain and can be dangerous if certain key .
Pls check the blew link to see the product detail information:
3.Anti glare
Anti-glare lighting reduces glare. This feature is particularly important for road users. Blinding lights can increase reaction time and lead to catastrophic results. Green Light LED adopts secondary optical light distribution design and concentrates 90% of the residual light into the central light intensity, thus greatly reducing the harmful glare and maximizing the protection of the community environment.
4. High light transmittance material
Using tempered glass or Japan PC lens , the light transmittance of the luminaire is further improved.Under lamps with the same efficiency, the brightness of Green light LED lamps will be 15% higher than that of ordinary LED light at the same distance of illumination. The advantage will become more obvious as the distance gets longer.It is also more durable and less likely to atomize.
5.CCT selection
Green light LED range from 2700K to 6500K on the current lamps. Yellow color looks more comfortable, which is beneficial for workers who are often exposed to artificial lighting in the workplace. However, white color allows us to see the true color of objects. The selection of color temperature according to the requirements of the site is also an important factor that will affect the later effect.
6.Avoid light pollution
While other companies are still studying how to maximize the light efficiency of lamps, we have begun to focus on environmental protection. The elimination of the influence of spill light on the community and the reasonable projection of light onto the site are the important reasons for us to sell to customers and customers to choose us at ease.
Pls check the blew link to see the product detail information:
7.Running cost of LED high mast lighting
In addition to the cost of the lights, we need to learn more about the cost of running high mast lighting.Energy efficiency is identified by looking at luminous efficiency in lumens per watt or LM/W.Halogen lamps have powers of 10 to 20 lm/W, HID lamps 60 to 80 LM/W, and LED 120 to 140 lm/W, which means LED can provide brighter lighting for the same amount of power. For a large lighting site, the reduction in total power means a significant reduction in the annual electricity bill.
For 10000W LED high mast lights, operating cost = 100000W x 5 hours x $0.25/1000 = $125 per day and $3750 per month. If halogen floodlights were used, this value would be 10 times higher due to their lower energy efficiency. Greatly reduced operating costs.
8. LED more energy efficient
Green Light LEDS have a high lumen output.For the same brightness requirements. LED always consume less energy than metal halides and HPS. Our LED lamps consume 130 lumens per watt, which is about twice as much as HID, and even 10 times as much as halogen bulbs.This is not only a reform of energy conservation and energy consumption, but also contributes to the reduction of carbon dioxide emissions, especially a large lighting site, which has been continuously reducing carbon dioxide emissions for decades and has played a positive role in protecting the environment.
9.Less maintenance
Choose durable lamps to save on maintenance costs. Because the high mast lighting is installed on the tower, the height is more than 30 meters, the cost of human maintenance is very high. But we didn’t have the ballasts of traditional lamps, and we didn’t have to replace them regularly, so we had much less maintenance.
Our outdoor LED lamps are IP66 waterproof to withstand heavy rain and thunderstorms. Our LED can even operate at -40 °C to 50°C, making them ideal for countries with heavy snow or year-round high temperatures.Basically, there is no problem of damage, is not to carry out maintenance measures.
10.Better lighting control
Our outdoor high pole LED projector ADAPTS to THE DMX512 protocol, so the basic all-purpose dimming system helps users easily adjust brightness. We’re looking for more and more intelligent controls because no one wants to run to the control room to turn off the lights on a rainy day or late at night. Intelligent control will be more and more convenient for our life.
Pls check the blew link to see the more detail information about the football field light design:
11. Advanced cooling system
Most of the high-power lamps on the market are die-cast aluminum radiator modules in which the chip operating temperature reaches 90℃ above. Light decays very quickly, usually with a lifetime of 2 to 3 years. But our Green Light USES finned radiators or superconducting radiators.The working temperature of the chip can be kept below 70℃. Thus, the reduction rate of optical decline in 5 years is below 20%.
12. More professional services
Every user wants to install the lighting system to achieve a satisfactory effect, so the early design simulation is very important. We have a professional design service team to provide customers with satisfactory design solutions before they place orders. Let the customer from the beginning of the completion of the project with high expectations.
If you haven’t made a decision after reading these 12 tips, you can contact our Green Light team directly for more advice. We are always working to help customers solve the most cost-effective lighting solutions.[email protected].
Pls check the blew link to see the more detail information about Cricket ground light design:
FAQ
1.Why is yellow light better than white?
We can produce 2700K~6500K LED color temperature.Yellow light is the most penetrating color in the early morning or special foggy weather, so it always provides a better line of sight for people working in special environments. But for the stadium, white light is more popular than yellow light, because the match scene needs to be close to the sun.
2.Why are high mast lights so high?
The design of the high mast light is to provide lighting for large areas, and the power of the lamp used is also very large. For LED, the power is generally more than 1000W.Only when the height is high enough can the high-power lamps give full play to their own performance and provide good uniformity for the large area of the site needed.
3.How much does it cost to a high mast?
8000-100 000USD. Generally speaking, a light pole over 30 meters is considered as a tall pole. However, the design of a tall pole needs to take the local maximum wind speed in the past 10 years as the reference, and the cost should be calculated based on the height and the bearing weight of the lamp to be installed.If it is some special shape lamp pole, also need according to the complexity of the process as the cost accounting.
4 thoughts on “How to select the high master lights – 12 tip from engineer”
Comments are closed.
erotik izle
24 Jul, 2020/6:21 pm
This should be the best collection of blogging website i ever found out.
greenlight
27 Jul, 2020/7:20 am
Thank you very much for your recognition. Any requirement pls contact with our team.
Marla Guthrie Dacy
31 Jul, 2020/4:26 pm
hola me encanta la cabecera de tu blog, es una creación personal? Marla Guthrie Dacy
greenlight
1 Aug, 2020/9:28 am
Sí, escribimos este aprendizaje de nuestro ingeniero